GW INSTEK MSO-2102E Mixed-signal oscilloscope (100Mhz, 2+16 channels logic)

Resolution
8 bit

:1mV~10V/div

Input Coupling
AC, DC, GND

Input Impedance
1MΩ// 16pF approx.

DC Gain Accuracy
±(3%)when 2mV/div or greater is selected

 

±(5%)when 1mV/div is selected;

Polarity
Normal & Invert

Maximum Input Voltage 
300Vrms, CAT I

Offset Position Range
1mV/div ~ 20mV/div : ±0.5V

50mV/div ~ 200mV/div : ±5V

500mV/div ~ 2V/div : ±25V

5V~10V/div : ±250V

Waveform Signal Process
+, -, ×, ÷, FFT, FFTrms ,User Defined Expression.

 
FFT:1Mpts 
FFT:Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris.

Trigger

Source
CH1 ,CH2, CH3, CH4, Line, EXT*

*dual channel models only

Trigger Mode
Auto (supports Roll Mode for 100 ms/div and slower), Normal, Single Sequence

Trigger Type
Edge, Pulse Width(Glitch), Video, Pulse Runt, Rise & Fall(Slope), Alternate,tme out, Event-Delay(1~65535 events), Time-Delay(Duration,4nS~10S), Bus


Holdoff range
4ns~10s

Coupling
AC,DC,LF rej. ,HF rej. ,Noise rej.

Sensitivity
1div

External Trigger 

Range
±15V

Sensitivity
DC ~ 100MHz Approx. 100mV

100MHz ~ 200MHz Approx. 150mV

Input Impedance
1MΩ±3%~16pF

Horizontal

Time base Range
1ns/div ~ 100s/div (1-2-5 increments)

ROLL: 100ms/div ~ 100s/div

Pre-trigger
10 div maximum

Post-trigger
2,000,000 div maximum. 

Time base Accuracy
±50 ppm over any ≥ 1 ms time interval

Real Time Sample Rate
Max.:1GSa/s (4ch model) 
Per channel 1GSa/s (2ch model) 

Record Length
Max:10Mpts

Acquisition Mode
Normal, Average, Peak Detect, Single

Peak Detection
2ns (typical)

Average
selectable from 2 to 256

X-Y Mode

X-Axis Input
Channel 1; Channel 3*

*four channel models only

Y-Axis Input
Channel 2; Channel 4*

 
*four channel models only

Phase Shift
±3° at 100kHz

Cursors and Measurement

Cursors
Amplitude, Time, Gating available;Unit:Seconds(s),Hz(1/s) ,Phase(degree) ,Ration(%)

Automatic Measurement
36 sets: Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Frequency, Period, RiseTime, FallTime, +Width, -Width, Duty Cycle, +Pulses, -Pulses, +Edges, -Edges, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF, Phase ,Cursor measurements

Control Panel Function

Auto counter
6 digits, range from 2Hz minimum to the rated bandwidth

Autoset
Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo Autoset

Save Setup
20set

Save Waveform
24set

Display

TFT LCD Type
8" TFT LCD WVGA color display

Display Resolution
800 horizontal × 480 vertical pixels (WVGA)

Interpolation
Sin(x)/x

Waveform Display
Dots, vectors, variable persistence (16ms~4s), infinite persistence

Waveform Update Rate
120,000 waveforms per second, maximum

Display Graticule
8 x 10 divisions

Display mode
YT ;XY

Interface

USB Port
USB 2.0 High-speed host port X1, USB High-speed 2.0 device port X1

Ethernet(LAN) Port
RJ-45 connector, 10/100Mbps with HP Auto-MDIX

Go-NoGo BNC
5V Max/10mA TTL open collector output

Kensington Style Lock
Rear-panel security slot connects to standard Kensington-style lock.

Logic analyser specifications

Sample Rate
Per Channel 1GSa/s

Bandwidth
200MHz

Record Length 
Per Channel 10M pts (max)

Input Channels
16 Digital (D15 - D0)

Trigger type
Edge, Pattern, Pulse Width, Serial bus (I2C, SPI, UART(RS232/422/485), CAN, LIN), Parallel Bus

Thresholds Quad
D0~D3, D4~D7,D8~D11 ,D12~D15 Thresholds

Threshold selections
TTL, CMOS(5V,3.3V,2.5V), ECL, PECL,0V ,User Defined

User-defined Threshold Range
±5V

Maximum Input Voltage
±40 V

Minimum Voltage Swing
±250 mV

Input impedance
101KΩ probe loading 8pF

Vertical Resolution
1 bit

AWG Specifications (MSO-2000EA only)

Channels
2

Sample Rate
200 Msa/s

Vertical Resolution
14 bits

Max. Frequency
25 MHz

Standard Waveform
Sine, Square, Pulse, Ramp, DC, Noise

Built-in ARB Waveform
Sinc, Gaussian, Lorentz, Exponential Rise, Exponential Fall, Haversine, Cardiac

Output Range
20 mVpp to 5 Vpp, HighZ;10 mVpp to 2.5 Vpp, 50 Ω

Output Resolution
1mV


Output Accuracy
2% (1 kHz)

Offset Range


±2.5 V, HighZ;±1.25 V, 50 Ω

Offset Resolution
1mV